Interpretation Response #PI-92-033
Below is the interpretation response detail and a list of regulations sections applicable to this response.
Interpretation Response Details
Jul 16, 1992
Mr. Dan H. Weaklend
Chief, Pipeline Safety Utilities Division
Arizona Corporation Commission
1200 W. Washington Street
Phoenix, AZ 85007
Dear Mr. Weaklend:
Thank you for your letter of June 5, 1992, suggesting regulatory actions to improve operator's corrosion control programs. Specifically, you suggested we drop the generic specification approach found in Appendix D of Part 192, and adopt instead a system-specific approach. Under this alternative, operators would (1) include corrosion control criteria and procedures in their operating and maintenance plans, and (2) determine the cause of each corrosion leak and take corrective action.
Because corrosion continues to be a major cause of pipeline accidents, we support your desire to see that operators do as much as possible to correct the problems. We are concerned, though, that deleting Appendix D, as suggested, would not solve the problem. Corrosion control is a complex science, the principles of which do not vary from system to system. So we see no good reason to allow variations in control criteria. In fact, lack of uniform criteria has been a problem in enforcing corrosion control under Part 195, which specifies no corrosion control criteria. Nonuniform criteria under Part 192 could further increase the enforcement workload by requiring inspectors to verify the legitimacy of criteria operators put in their plans.
The Appendix D criteria were based on the National Association of Corrosion Control (NACE) Standard RP-01-69. NACE recently revised this standard, and we expect it will petition us to adopt the revised version. The pipeline industry's use of this new standard should assure consistent and correct corrosion control.
As for procedures and leak investigations, these topics are already regulated. Section 192.453 requires gas operators to follow procedures in applying corrosion control. Similar requirements are in §§ 193.2625 and 195.402(c)(3). Determining the cause of corrosion leaks is covered by §§ 192.617, 193.2515, and 195.402(c). We agree that operators with numerous corrosion leaks should be asked to explain their actions or lack of action, but the rules needed to require operators to take proper corrective actions are already in the regulations.
If you have any further concerns, please call Jim Thomas, Director, Southwest Region at (703) 750-1746.
Sincerely,
Cesar De Leon
Director, Regulatory Programs
Office of Pipeline Safety
Regulation Sections
| Section | Subject |
|---|---|
| § 195.402 | Procedural manual for operations, maintenance, and emergencies |